Item | Unit | Standard/Technical Requirement | Test Result |
Silicon Dioxide (SiO₂) Content | % | ≥90.0 (GB/T 27690-2023)<br>≥85.0 (ASTM C 1240)<br>≥90.0 (EN 13263) | 92.32 |
Moisture Content | % | ≤2.0 (GB/T 27690-2023)<br>≤3.0 (ASTM C 1240)<br>≤2.0 (EN 13263) | 0.1 |
Loss on Ignition (LOI) | % | ≤4.0 (GB/T 27690-2023)<br>≤6.0 (ASTM C 1240)<br>≤4.0 (EN 13263) | 2.12 |
Fineness (Residue on 45 μm sieve) | % | ≤5.0 (GB/T 27690-2023)<br>≤10.0 (ASTM C 1240)<br>≤5.0 (EN 13263) | 2.5 |
Specific Surface Area | m²/kg | ≥15000 (GB/T 27690-2023)<br>≥15000 (ASTM C 1240)<br>≥15000 (EN 13263) | 28170 |
Water Demand Ratio | % | ≤125 (GB/T 27690-2023)<br>≤125 (ASTM C 1240)<br>≤125 (EN 13263) | 110 |
Total Alkali Content (Na₂O+0.658K₂O) | % | ≤1.5 (GB/T 27690-2023)<br>≤2.0 (ASTM C 1240)<br>≤1.5 (EN 13263) | 1.1 |
Radioactivity - Internal Exposure Index (Iₐ) | - | Iₐ ≤1.0 (GB/T 6566-2010)<br>(Not specified in ASTM/EN, regional requirement) | 0.15 |
Radioactivity - External Exposure Index (Iᵧ) | - | Iᵧ ≤1.0 (GB/T 6566-2010)<br>(Not specified in ASTM/EN, regional requirement) | 0.2 |
Activity Index (7d) | % | ≥105 (GB/T 27690-2023)<br>≥105 (ASTM C 1240)<br>≥105 (EN 13263) | 120 |
Alkali-Aggregate Reaction Inhibition | % | 14d expansion reduction ≥35 (GB/T 27690-2023)<br>(Not specified in ASTM/EN) | 66 |
Chloride Ion Content | % | ≤0.02 (GB/T 27690-2023)<br>≤0.01 (ASTM C 1240)<br>≤0.02 (EN 13263) | 0.01 |
Chloride Ion Penetration Resistance (28d electric flux ratio) | % | ≤40 (GB/T 27690-2023)<br>(Not specified in ASTM/EN) | 30 |
Standard Compliance Notes
• Chinese Standard (GB/T 27690-2023): All test results meet the mandatory requirements of the latest national standard for silica fume for cement and concrete.
• American Standard (ASTM C 1240): The product meets or exceeds the key performance requirements of ASTM C 1240, with minor differences in allowable limits for moisture content, LOI, and total alkali content that are fully satisfied by the test results.
• European Standard (EN 13263): The product aligns with EN 13263 specifications for silica fume in concrete, matching the strict limits for fineness, specific surface area, and chloride ion content.
Typical Applications
• High-strength, high-performance concrete (HPC/HSC) for bridges, dams, high-rise buildings
• Shotcrete and tunnel lining concrete
•Oil well cement and geothermal well cement
• Refractory castables and monolithic refractories
• Self-compacting concrete (SCC)
• Marine concrete and corrosion-resistant structures
• Dry-mix mortar and grout
Recommended Usage & Dosage
• Concrete: 5% - 10% by mass of cementitious material (cement + fly ash/slag)
• Refractory Materials: 8% - 15% by mass of binder
• Mortar/Grout: 5% - 12% by mass of cement
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.